Conducted-cooled stacked array laser DSCC-808a-1200W-GD05
. Main features:
Gold and tin package, narrow spectral width, high reliability, peak value power
. Applied range:
Pump, industry, medical care, scientific research
. Photoelectric parameters:
Parameter (25℃) |
unit |
DSCC-808a-1200W-GD05 |
Optical parameters |
|
|
The central wavelength is λc |
nm |
806 |
The central wavelength deviation |
nm |
±2 |
half band width |
nm |
<3 |
output power /bar |
W/bar |
200 |
Barbar number |
pcs |
6 (1- -8 Optional) |
Bar spacing |
mm |
0.73(0.43/0.73/1.13 Optional) |
Fast-axis divergence angle (95%) |
degree |
<3 |
Slow-axis divergence angle (95%) |
degree |
<10 |
Polarization mode |
/ |
TE |
Electrical parameters |
|
|
working current Iop |
A |
<250 |
threshold current Ith |
A |
<25 |
working voltage Vop |
V/bar |
≤2 |
service frequency |
Hz |
1--100 |
pulse width |
μs |
1--1000 |
duty cycle |
% |
≤2% |
life span |
shot |
>1E9 |
enviromental parameter |
|
|
working temperature |
℃ |
-45~60 |
storage temperature |
℃ |
-55~85 |
. Notes for use:
- Fast axis can be compressed according to customer requirements to meet the spot requirements of different shapes.
- Please avoid using and storing them in the condensation environment.
- Over the rated working current will shorten the service life of the device.
- Working at higher temperature will reduce the power and shorten the service life of the device.